Onsite Video Clips of the V-inline performing 2-way and 3-way separation
|
View Slide Show of BP Gulf Oil Cleanup Trials July 2010 |
The Case Studies listed above summarize the results of the V-inlineSeparators for different applications. These include bulk oil separation to improve the existing system’s discharge water quality and a complete turnkey separation skid designed specifically to meet customers discharge requirements.
Data from a recent project is below. In addition to the excellent separation performance, the V-inlineSkid also demonstrated that the performance was not affected by changes in flow (over a range from 26GPM–44 GPM - approximately 2 to 1 ratio) or influent concentrations (over a range of 1200ppm-17200ppm - approximately 17 to 1). No modifications were made to the V-inlineduring variations in flow rate or inlet concentration. Inlet pressure was approximately 5psig.
Run # | Flow (gpm) | Inlet Oil (ppm) | V-inline Clean Water Oil2 (ppm) | Skid discharge Clean Water (ppm) | V-inline Efficiency2 (%) | Skid Efficiency (%) | Efficiency With Polisher (%) |
---|---|---|---|---|---|---|---|
1 |
44 |
3,490 |
N/A |
1 |
|
|
99.96 |
2 |
44 |
3,000 |
N/A |
2 |
|
|
99.93 |
3 |
44 |
2,070 |
143 |
15 |
93.1 |
99.3 |
|
4 |
44 |
2,120 |
264 |
29 |
87.5 |
98.6 |
|
5 |
44 |
1,190 |
191 |
99 |
83.9 |
91.7 |
|
6 |
45 |
1,280 |
127 |
33 |
90.1 |
97.4 |
|
7 |
31 |
1,410 |
122 |
34 |
91.3 |
97.6 |
|
8 |
31 |
17,200 |
610 |
36 |
96.5 |
99.8 |
|
9 |
31 |
2,760 |
77 |
30 |
97.2 |
98.9 |
|
10 |
31 |
7,510 |
129 |
39 |
98.3 |
99.5 |
|
11 |
26 |
1,729 |
84 |
23 |
95.1 |
98.7 |
|
12 |
26 |
1,494 |
97 |
19 |
93.5 |
98.7 |
|
Notes:
Data Analyzed by the Onsite Laboratory
2 Refers to the first V-inline